Step 3: Switch the breaker and fuses to OFF position, in order to avoid electric arcs and the risk of
damage.
Step 4: Use two battery cables. Remove 30 mm of the insulation sleeve (a), insert into cable ring
terminal and crimp it with a dedicated crimping tool (H type), then insert it into the connector
(b).
(a)
Step 5: Make sure the cables are correctly connected.
Step 6: Plug the battery connector into IMEON's "DC BATTERY"
socket.
Step 7 : The battery parameter can be done on IMEON MANAGER
(refer to inverter configuration section).
WARNING: Do not switch the circuit breaker when the IMEON is under load, it can damage the
inverter.