8.2 Regular maintenance

FR
EN
Check the following points to ensure proper operation of the whole solar system at regular intervals.
WARNING: Before cleaning this inverter, be sure to turn off all the breakers (AC breaker, battery
breaker and PV DC breaker).
WARNING: A battery can present a risk of electrical shock and high short-circuit current. Do not
dispose of batteries in a fire. The batteries may explode. Do not open or mutilate batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
 Ensure the cleanliness of the air circulation (ventilation of the inverter).
 Clean this inverter, during the cool time of the day, whenever it is visibly dirty.
 Periodically inspect the system to make sure that all cables and connectors are securely
fastened in place.
WARNING: There are no user-replaceable parts inside IMEON. Do not attempt to service or
90
IMEON INVERTER
Voltage on AC Output exceeds minimum voltage specification.
Voltage on AC Output overpasses maximum voltage specification.
Power on AC Output overpasses maximum power specification.
Voltage on DC bus overpasses maximum voltage specification.
Voltage on Battery overpasses maximum voltage specification.
Battery charging current overpasses specification of the inverter.
swap the unit yourself. Please contact the technical support with the following above
warning or error code
Manuel d'installation / Installation guide IMEON Inverter – Rev B.5
PV input current overpasses specification.
PV2 input current overpasses specification.
PV input voltage overpasses specification.
PV2 input voltage overpasses specification.
Neutral / Ground wires are reversed.