Safety and refrigerant R290
This appliance contains R290 refrigerant. R290 is a
1.
refrigerant that complies with European directives. Never
puncture the cooling circuit; R290 is flammable (GWP 3)!
For the dehumidifying process, never us any refrigerant
2.
other than what the manufacturer recommends.
This appliance must be used and stored in a place that has
3.
no sources of ignition, such as an open fireplace or gas and
electric appliances that are running.
Do not puncture any of the components of the cooling
4.
circuit and do not set the appliance on fire.
If the appliance is installed, operated or stored in a non-
5.
ventilated room, then you must take measures for
preventing fire or explosion caused by leaking refrigerant.
Make sure that there are no sources of ignition in the same
area (such as fire, stoves, electric appliances with sparks,
burning cigarettes, etc.).
The appliance must be stored in a way that prevents
6.
mechanical faults.
Do not install, use or store this appliance in a room with a
7.
floor surface that is smaller than 12 m² (Coolsmart 90 &
120).
R290 is odourless so you will not smell a leak!
8.
Persons working or interfering with cooling circuits must be
9.
in the possession of the appropriate certification, which is
issued by a certified body and in which it is stated that the
person in question is competent to handle cooling agents in
compliance with a specific assessment recognised by
associations in the sector.
The repairs must be carried out based on the
10.
recommendations of the appliance's manufacturer.
Maintenance and repairs that require the assistance of
other qualified personnel must be carried out under the