Wiring; Battery Installation - Lorentz PSk2-7 Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

15.3.6 Wiring

The SmartStart to PSk2 cable is prewired and connected.
The generator auto start connections are made using the
GENlink plug inside the SmartStart. These terminals are
marked NO and Com ("Figure 62: SmartStart board" on
page 91). The ancillary output is on the right side of the
GENlink. The connector type is a spring connection, press
the orange button with a small screwdriver and then insert
the stripped cable. 10 mm of bare conductor is required for
a good connection.
Figure 62: SmartStart board
custom cable to
controller
GENlink

15.3.5 Battery installation

The SmartStart is powered by a battery. The battery is
charged by the controller through the supplied custom
cable. The required battery must be ordered separately.
If the battery is not delivered by LORENTZ, it must meet the
following characteristics:
ƒ Genesis NP-12 or similar. Sealed 12V AGM lead acid
ƒ Min. capacity: 7Ah
ƒ Max. dimensions without connector: 151 x 70 x 95 mm
ƒ height overall max. 100 mm (3.94 in)
ƒ Connector: 4.8 mm (0.189 in) faston tabs
It is possible to purchase a battery from LORENTZ. Contact
your distributor for further information.
SmartStarts delivered by LORENTZ with batteries included
must be recharged every 6 months during storage.
battery
plug
secondary output
(auxiliary)
SmartSolution
battery
(5.94 x 2.56 x 3.74 in)
91

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Psk2-9Psk2-15Psk2-21Psk2-25Psk2-40