Operating the Pump

11.4 Parameter settings

NOTE – Please always refer to the
PumpScanner documentation available on
partnerNET for the latest developments.
It is highly recommended to make an initial configuration of
the DataModule inside the PSk2 controller using LORENTZ
PumpScanner, our Application for Android smartphones.
To gain access to the DataModule using PumpScanner,
the installation must be registered online in partnerNET at
"Sites" first. The "License list" within PumpScanner settings
must be updated afterwards.
For detailed instructions on how to set up a "Site"
and how to install and use PumpScanner read the
"PS Datamodule and PumpScanner" manual. It is
available on partnerNET.
NOTE – Always make sure that the latest
version of PumpScanner is installed on
your device. Make sure that the DataMod-
ule is equipped with the latest firmware
version. The firmware can be checked and
updated using PumpScanner.
WARNING – If the pump spins without
lifting water there is a chance of pump
damage caused by the water overheating.
Check whether the latest version of PumpScanner is
installed on your android device. Check the PumpScanner
manual for help.
1.
Make sure that the physical installation is completed
and that all connections have been double checked
for correct connection.
2.
Connect the power to the PSk2 controller but leave
the ON/OFF toggle switch of the PSk2 controller in
position OFF. The pump must not run at this point.
3.
Connect to the pump controller using PumpScanner
as per the PumpScanner manual.
4.
Check the PSk2 controller Firmware version as per
the PumpScanner manual and update it if asked by
PumpScanner to do so.
5.
Click on "Pump profile" in PumpScanner to access the
parameter settings for the PSk2 controller. Do not for-
get to scroll to the bottom and SAVE the changes
before leaving the "pump profile" menu.
Controller and pump unit – Use the pull down menu to
select the correct controller and the correct pump unit.
Cable length and cable size – Enter here the length and
size of the installed motor cable to allow PumpScanner to
calculate the correct cable losses for the pump system.
Flow meter and pressure sensor – If any Water Meter
or Pressure Sensor is connected to the PSk2 controller enter
the characteristics of the sensors as described.
Sun Sensor – The Sun Sensor is used to stop the pump if
the solar power is insufficient. In weak sun conditions the
pump may spin without lifting water all the way to the
outlet.
The remaining options are explained in the PumpScanner
manual.
Always click the SAVE Button on the bottom of the pump
profile menu to keep the changes.
The pump profile configuration is done and the pump can
be switched ON.