Controller Installation
Table 6: Terminal explanation
Socket
Terminal
Ground
DC POWER IN
Well probe
Remote switch
Water detection
sensor
SunSensor
module
Analog input 1
(4-20mA)
Analog input 2
(4-20mA)
Water meter
24V OUT (max.
30mA)
12 - 24 V IN
Pump
AC output
Connection
connect to protective ground
GND
wire (PE)
connect to positive terminal of
+
PV module
connect to negative terminal of
PV module
1
connect to NC
2
connect to COM
3
connect to NC
4
connect to COM
5
connect to Signal
6
connect to COM
7
connect positive (+)
8
connect negative (–)
9
connect positive (+)
10
connect negative (–)
11
connect positive (+)
12
connect negative (–)
13
connection to NC
14
connection to COM
15
connect positive (+)
16
connect negative (–)
17
connect positive (+)
18
connect negative (–)
L1
connect to L1 phase of motor
L2
connect to L2 phase of motor
L3
connect to L3 phase of motor
connect to protective motor
GND
ground wire (PE)
Function
Connect grounding
Please refer to „8.6 Grounding" on page 33
The following conditions apply "Table 5: Technical
data of PSk2 controller" on page 24
Connect a well probe or float switch to terminal
1+2 to protect the pump system from running dry.
Every pump system must be equipped with a dry run
protection. Connect a jumper wire between 1+2 if
not used.
Connect a tank switch, pressure switch or any other
suitable remote switch to terminal 3+4.
Connect a jumper between 3+4 if not used.
Connect water detection sensor for surface pumps –
for submersible pumps a jumper wire is needed
between 5+6.
Connect the SunSensor to terminal 7+8 and observe
polarity. The SunSensor is included with the PSk2
controller and needed to protect the pump.
4 –20 mA signal sensor supply voltage +24 V load
impedance 100 Ω; observe correct polarity
4 –20 mA signal sensor supply voltage +24 V load
impedance 100 Ω; observe correct polarity
input impulse – reed switch; impulse rate needs to
be set up with PumpScanner; max. rating 1 kHz set-
ting range: adjustable by PumpScanner application
for service purpose – use only if instructed by the
manufacturer
for service purpose – use only if instructed by the
manufacturer
the following conditions apply "Table 5: Technical
data of PSk2 controller" on page 24