Initial Start-Up; Filling Pump With Water - Lorentz PSk2-7 Manuel D'installation Et De Fonctionnement

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

56
Pump Installation

9.3.5 Initial Start-up

CAUTION – Never start the pump if it is
not filled with water and has not been
vented. The pump and suction pipe must
be fully filled with clean water otherwise
the pump will be damaged.

9.3.5.1 Filling Pump with Water

The pump and the whole suction pipe must be fully filled
with clean water.
If the water level is higher than the pump inlet:
1.
Close the gate valve in the outlet pipe and loosen the
air vent screw.
2.
Open the gate valve in the suction pipe slowly.
3.
Tighten the air vent screw when water streams out
continuously.
If the water level is below the pump inlet:
Suction pipeline and pump must be filled with water.
1.
Close the gate valve in the outlet pipe and open the
gate valve in the suction pipeline.
2.
Loosen the air vent screw and fill the water into the
pump through the filler pipe.
3.
Fasten the air vent screw after the pump and the
suction pipeline are completely filled with water.
CAUTION – Installing a suitable filler pipe
is highly recommended for proper priming
of the pump system. A pump system which
is not primed completely will likely get
damaged when it is switched on.
CAUTION – A nonreturn valve must be
installed at the start of the inlet pipeline
otherwise it is impossible to prime the
pump successfully.
WARNING – Do not start the pump until it
has been filled completely with water.
WARNING – Make sure that the installed
shutoff valves in the suction and pres-
sure lines are completely open during
operation, the pump must never run with
shutoff valves closed!
Figure 37: Vent and drain holes
Air vent hole
Water drain hole

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Psk2-9Psk2-15Psk2-21Psk2-25Psk2-40

Table des Matières