Pump Accessories Installation

10.3 Water meter installation

For information on the water meter installation, please refer
to the manual of the manufacturer. Pay attention to the
installation position, flow direction and the calming section.
Basic rule: The water meter should have 10 nominal
diameters straight pipe ahead of the meter and 5 nominal
straight pipe diameters after to ensure proper flow through
the meter.
Figure 46: Water meter installation
10×D
Figure 47: LORENTZ water meter
D
5×D

10.4 Level sensor installation

The LORENTZ range of liquid level sensors use pressure to
measure the level of water in a well or tank. The sensors
can be used for long term water level monitoring and also
for pump control in applications where a well probe cannot
be used.
The Level sensor is connected to one of the two Analog
Inputs of the controller. Configuration of the sensor is done
with PumpScanner
For further information about the level sensor please refer to
the COMPASS datasheet.
Figure 48: LORENTZ Liquid Level Sensor