POWER SUPPLY

INSERT THE BATTERIES
Open the battery compartment cover (5) by use of a
coin. Insert 1 x CR2 battery (ensure correct polarity).
Close the battery cover - see the instructions below.
If the battery status indication shows
the battery has to be replaced. Otherwise low
battery power may cause wrong measuring results.
We recommend to take off the battery in case you do
not use the unit for a longer time.

OPERATION

Aim the GeoDist®600LR towards
the object to be measured and focus
the eyepiece with knob (7).
POWER ON AND OFF THE INSTRUMENT
Power on the unit with button
without activity the instrument will power off auto-
matically.
ANGLE CALIBRATION
This instrument has been calibrated by the factory.
In case of wrong measuring results it should be re-
calibrated manually. Power off the unit and keep the
power button pressed for 2 seconds to enter into the
calibration mode. „ANGLE CAL " will appear in the
display. Hold the instrument straight for some seconds
to complete the calibration. In case the calibration fails
the instrument will power off and return to the factory
calibration.