Troubleshooting
FAULT
The unit will not switch on
The forward speed is not correct
Tonnage counter reading incorrect
Calibration test
Shutters open to maximum then to minimum
The unit switches on correctly, but the actuators do
not move
Surface area counter reading incorrect
Application rate incorrect
Check
- unit / power cable connections
- power cable fuses
Check
- connection on unit
- distance between the detection ring / sensor
- that the detection ring is rotating correctly
- sensor wire continuity
- 100m coefficient
Check
- connection / machine
- working width
- forward speed
- product extraction density (T factor)
- shutter opening and closing
Check
- calibration factor (T)
- that the shutters are open
Repeat the test
Check
- tractor forward speed coefficient.
- spreading width (24.00 beware of the decimal point)
Check
- the fuses
- the battery power supply
Check
- connection / machine
- working width
- forward speed
Check
- programmed flow rate
- product extraction density (T factor)
- conveyor belt speed (S, M or F)
- spreading width
- tractor forward speed
- shutter opening
- positioning of application rate adjustment plates
inside the hopper
- actuator travel
- tramlining