English
• carry out scheduled maintenance as provided in the agreement

25. Troubleshooting

DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Problem
The counter
• power black-out
stops and
• master switch turned off
does not re-
start
The engine is
• screws and bolts are not tight-
noisy
ened
• the counter is not level
Condensate
• poor room conditions
• the demisting system does not
work
Water leaks,
• counter drains are obstructed
bad smell
or damaged
• joints are missing between cabi-
nets or sealed incorrectly
i
in all cases not described or where it is not possible to solve the problem by following these
directions, call the nearest authorised after-sales centre.
44
Possible causes
once the electrical supply has been restored, check that all the electrical
equipment in the shop will restart without triggering overload protection
devices; otherwise, modify the system to differentiate enabling of the vari-
ous devices
i
If power is not restored in a short time, store the goods in a cold room to
maintain the storage temperature.
Possible solutions
• check the cause of the black-out
• turn on the switch
• tighten the bolts and screws
• level the counter
• check the position of the counter inside the
store
• check the operation of fans and wiring
• free the drain
• repair or replace the drains
• install and seal the joints