VersiCharge Gen3 IEC charging unit with upstream personal and line protection for additional safety
5SL4 & 5SL6 MCB
VersiCharge Gen 3 IEC configurations and optional settings:
Order No.
8EM1310-2..0.-....
8EM1310-3..0.-....
Product recommendation for upstream personal and line protection per configuration:*
Variant and Rated
Current
VersiCharge
Single Phase
(7.4 kW, 1P+N)
VersiCharge
Three Phase
(22kW, 3P+N)
* The correct selection of the installation components is the responsibility of the customer
Supplementary information on components and variants:
Tripping characteristic C is recommended for applications
with high start-up current and power peaks. For a higher
degree of protection components with tripping
characteristic D are optionally available.
Depending on the case of installation and country-specific
regulations, different pole configurations may be required.
The recommended products refer to the household
applications. For systems with several charging stations the
MCBs of the 5SY4 and 5SY6 series are recommended,
which offer additional protection.
For additional information and more products please visit:
VersiCharge AC Wallbox IEC
A5E50300544-AA, 10/2020
Upstream protection for electric installation*
*Schematic example
Specification
Single Phase 7.4 kW
Three Phase 22kW
MCB, Characteristic C
10 A
5SL6510-7
13 A
5SL6513-7
16 A
5SL6516-7
20 A
5SL6520-7
32 A
5SL6532-7
10 A
5SL6510-7
13 A
5SL6513-7
16 A
5SL6516-7
20 A
5SL6520-7
32 A
5SL6532-7
Max. current (default)
1 x 32A
3 x 32A
RCCB, Type A
(Recommended)
5SV3311-6
5SV3312-6
5SV3314-6
5SV3342-6
5SV3344-6
According to IEC 61851-1 , a 30mA RCCB Type A is
sufficient, due to the 6mA DC residual current monitoring
integrated in the wallbox. Local regulations may differ and
have to be considered.
The listed prouct recommendations refer to RCCBs with
instantaneous tripping. Components with delayed tripping
(variant KK01) are also suitable for installation in
households and offer an additional degree of robustness.
https://mall.industry.siemens.com/
5SV3 RCCB
Type A and B
Setting Options
10 A / 13 A / 16 A / 20 A / 32A
10 A / 13 A / 16 A / 20 A / 32A
RCCB, Type B
(optional if required)
5SV3321-4
5SV3322-4
5SV3324-4
5SV3342-4
5SV3344-4