e) List of changeable parameters
Parameter
Authentification
System Password
Temperature unit
Time display mode
Adaptive timing
Standby mode timeout
FMC
FMC temperature
Standby temperature
Idle Timing
Buzzer reset timer
Buzzer volume
Quality alarm
Temp meas. Trim offset
Temp meas. Trim slope
Twin mode off
Display intensity
Skip temp. setting
Hide sp
Temp. if prg.run
Screen saver mode
Reset factory def
Fonction
Access code to programming mode
Access code
Temperature indication
Time display
Fry Computer
Time for Standby
Fat melting cycle
End temperature of the FMC
Temperature setting for the Standby
Time to switch into FMC after switching on the
control panel
Buzzer settings
Sound volume
Alarm after the last frying cycle.
Survey of a chips scuttle.
Adjustment of the measured temperature
Adjustment of measure cycle
Synchronisation of basket lifts (Models 412)
Intensity of luminosity
Allow start frying cycle by pressing twice the " P"
button before set temperature is reached
Display set temperature after the start of a frying
cycle
Economy mode of the display by non use of the
fryer
Back to factory default settings
Setting / Value
disabled : inactive
enabled : active
Corresponds to the Quick Access buttons
( 4 digit code )
degC : Celcius
degF : Fahrenheit
elapsed : real time
remaining : count down
disabled : inactive
enabled : active
Adjustment between: 00 :00 / 4 :15 : 00
If time is set to 00 :00, the Standby is inactive
disabled : inactive ( continuous heating)
enabled : active
Adjustment between: 30 / 90°C
Adjustment between: 30 / 120°C
If time is set to 00 :00 the switch over is manual
Adjustment between: 00 :00 / 00 : 30
If time is set to 00 :00 the reset is manual by the "P" or
"Quick Access" button
low / medium / high
disabled : Inactive
enabled : Active
Adjustment between: 00 :00 / 9 : 59 : 59
Adjustment between: -10 / 10 °C
disabled : Inactive
enabled : Active
Auto / low / medium / high
disabled : Inactive
enabled : Active
disabled : Inactive
enabled : Active
After start of frying cycle, the set temperature becomes
darker
Logo : Logo frifri
Oil temp : Oil temperature
State : state