Functional description of operating mode Energy Manager
Changing the
operating mode
Response to power
failure
Functional description of operating mode SCU
Start of charging
process
Controlling the
charging process
Changing the
operating mode
Response to power
failure
Wechs el ein- auf z weis paltig
By using the Charge APP during a charging process:
 Change to operating mode "Manual (Remote)".
The change of operating mode will apply to the on-going charging process. The following
charging process is carried out according to the mode selected in the user settings of the
Charge APP.
In the user settings of the Charge APP:
 Changing to all operating modes configured during the setting-up process.
The change of operating mode will apply for the on-going and subsequent charging processes.
By using the service interface:
 Changing to all operating modes configured during the setting-up process.
The change of operating mode will apply for the on-going and subsequent charging processes.
The response to power failure is configured during the setting-up process.
 The charging process is aborted (default with RFID card reader).
 The charging process is continued (default without RFID card reader).
With RFID card:
 Authentication with valid RFID card
By using the higher-level back-end system:
 Control takes place completely over the higher-level back-end system.
By using the multi-function button:
 Terminating the charging process (stop)
The stop function with the multi-function button must be enabled during the setting-up
process.
With RFID card:
 Terminating the charging process (stop, with the same card used for starting the charging
process)
In operating mode "SCU", all functions of other operating modes are suspended. Using
the Charge APP is not possible.
By using the service interface:
 Changing to all operating modes configured during the setting-up process.
The response to power failure is configured during the setting-up process.
 The charging process is aborted (default with and without RFID card reader).
 The charging process is continued.
36