Troubleshooting
Failsafe Level 0
Only "ASF" detected and displayed.
The Marine Climate System will shut down and will not restart until the fault
is repaired.
Once the fault is repaired the Marine Climate System will restart.
Failsafe Level 1
All actions in level 0 plus all other faults detected but not indicated.
The system shuts down for 2 min or until the fault is cleared, whatever is
longer.
The system will restart if the fault is cleared.
Failsafe Level 2
All actions same as level 0 and 1. Faults are indicated.
The system shuts down for 2 min or until the fault is cleared, whatever is
longer.
Failsafe Level 3
All actions the same as level 0, 1 and 2.
The system shuts down for 2 min or until the fault is cleared, whatever is
longer.
The system will lockout after four consecutive "HPF" or "LPF" faults.
To clear the lockout:
Pressing the Power Button once to Off Mode.
Pressing the Power Button again to On Mode.