_BA_MCS.book Seite 18 Donnerstag, 2. April 2009 9:56 09
Programming
Program
Description
number
P-10
Display Brightness
Control
P-11
Display ºF or ºC
P-12
Cycle Pump With
Compressor or
Continuous Pump
P-13
Reverse Fan Speeds
During Heating Mode
P-14
Continuous Fan or
Cycle Fan with
Compressor
P-15
Reverse Cycle Heating
or Electric Heat Only
Option Installed (cool-
ing only units)
P-16
Fan Motor type selec-
tion Shaded Pole or
Split Capacitor.
P-17
Reset Memorized
Programming Defaults
P-18
Reserved for Future
Option
P-19
Reserved for Future
Option
P-20
Filter Threshold
(x10 hours)
P-21
Current Filter Time
(x10 hours)
P-22
Voltage Calibration
(Volts)
Note
I
Should any programming problems or confusion occur, reset the
Memorized Default Settings by entering the program mode and
setting P-17 to "rSt".
If recent programming changes were made but not saved, the reset
will return to the last saved defaults, which could differ from the
factory defaults.
18
Default
Range
9
4 = Low
13 = Maximum
F
F = Fahrenheit displayed
C = Celsius displayed
OFF
OFF = Cycle with compressor
On = Continuous pump
rEF
nor = Normal fan operation
rEF = Reversed fan in heating
con
CYC = Cycle fan with compressor
con = Continuous fan operation
nor
nor = Reverse cycle heating
ELE = Electric heater installed
SC
SP = Shaded pole fan motor
SC = Split capacitor fan motor
nor
rSt = Reset defaults
nor = Normal
00
00 – 250
x10 Hours Using
Current Filter
AC Voltage
MCS5, MCS15