Secondary Parameters Table

18
Secondary Parameters Table
Secondary
parameters
Gas pre-flow time
Wire creep speed
Start energy (%)
Start time
Start wire feed speed
Start welding voltage
Start slope time
Second slopetime
SpUp-Arc length corr. 2
Second energy (%)
Second wire feed speed
Second voltage
Welding time
Interval idle time
Crater fill slope time
Crater fill wire feed speed
Crater fill voltage
Crater fill energy (%)
Crater fill time
Wire burnback time
Gas post-flow time
Arc end detection
Tab. 3:
Secondary parameters
02.20
Mode
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x x
x
x
x
x
x x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
909.3059.9-03
Resolu-
Factory
Units
tion
setting
s
0.1
0.1
m/min
0.05
1
(0.1)
%
1
100 (TIG)
100 (MIGMAG)
125 (MMA)
s
0.1
0,1 (TIG)
1,0 (MIGMAG)
1,0 (MMA)
m/min
0.05
3.5
(0.1)
V
0.1
18
s
0.1
0.2
s
0.1
0.2
%
1
100
%
1
50
m/min
0.05
3.5
(0.1)
V
0.1
18
s
0.1
1.0
s
0.1
1.0
s
0.1
0.5
m/min
0.05
3.5
(0.1)
V
0.1
18
%
1
50
s
0.1
1.0
%
1
100
s
0.1
0.5
%
1
100
Range
Only with..
0.0...99.9
0.5...25
10...200
0.0...99.9
2-stroke
(MMA, TIG)
0.5...25
4-stroke Individual
10...45
4-stroke Individual
0.0...99.9
4-stroke Individual
0.0...99.9
4-stroke Individual
50...199
SpeedUp
10...200
4-stroke Individual
0.5...25
4-stroke Individual
10...45
4-stroke Individual
0.1...99.9
Spot spacing
0.1...99.9
Interval
0.0...99.9
Crater fill on
0.5...25
Crater fill on
10...45
Crater fill on
10...200
Crater fill on
0.0...99.9
Crater fill on, 2-stroke
0...400
0.1...99.9
0...200