13 .5 Main parameters

Parameter
Wire feed in %
(positive correc-
tion)
Wire feed in %
(negativecorrec-
tion)
Displayed as correction value for settings at
turning knob 61.
Wire feed in
m/min
Displayed as speed value in m/min after
setting with turning knob 61.
Material thick-
ness (at selected
characteristic
line)
Must-value weld-
ing voltage (in
manual mode,
only Control Pro)
Welding step (in
manual mode)
Tab. 6:
Main parameters

13 .6 Secondary parameters

 Press the mode key 60 for at least 2 sec-
onds.
9 The 7-segment display 47 displays the
secondary parameter code and value al-
ternately (BasicPlus).
9 The 7-segment display 47 displays the sec-
ondary parameter value, the 7-segment
10.13
0
-
-
-
-
V
-
-
-
-
display 55 displays the secondary param-
eter code (ControlPro).
 Press the mode key 60 until the required
secondary parameter code is displayed.
 Set the required secondary parameter
value using turning knob 61.
 Exit the secondary parameter by pressing
the mode key 60 for at least 2 seconds.
-80..
+99
Parameter Code
Gas pre-flow
0,5..
25
Creep in
speed
Spot welding
time
-
Backburn time
Gas post-flo
-
Intervalltime
ON
1..6,
Interval time
1..7
OFF
1..12
Software Ver-
sion
Must-value
welding volt-
age instead of
material thick-
ness
Tab. 7:
Factory
setting
Range
0,1 s
0,0...10,0 s
2,0 m/min
1,0...15,0
m/min
1,0 s
0,1...10,0 s
100 %
0...300 %
0,5 s
0,1...20,0 s
1,0 s
0,1...10,0 s
0,2 s
0,1...1,0 s
-
off
off/on
Secondary parameters
Mode
x x x x
x x x x
x
x x x x
x x x x
x
x
x x x x
x x x x
- 49 -