Main menu table
Main menu
M4 Settings
M5 User Interface
02.20
Sub-menu
M4-8 Torch / aux. drive
0 no Push Pull
1 Analogue Push Pull
2
...
31
M4-10 CO2 Manual
Off
On
Analogue PP Adjust
0...100 (40)
Analogue PP Direction
0 / 1 (0)
Gas monitor
0.0...25 (2.0) l/min
On...Off (On)
Water surveillance delay
1...100 (10)
M4-15 Standby
5, 10, 15, 30, 45, 60, 90, 120 min, Off
(Off )
M4-16 Screensaver
5, 10, 15, 30, 45, 60, 90, 120 min, Off
(30)
M4-18 compensation mode
Welding cable length
welding circuit resist.
Welding cable length
10...100 (10)
welding circuit resist.
(10)
M5-1 Display brightness
All LEDs
LCD contrast
Here you can select a connected torch / aux. drive.
For Push Pull preparation (hardware), only 1 (analogue Push
Pull) is available as a standard and setting value.
With an installed Push Pull function (upgrade), the standard
value is 0 (no Push Pull) and all values 0 to 31 are available.
Here you can select a CO2 optimised setting for manual weld-
ing processes
Here you can set the speed correction value of the Push Pull
torch
Here you can set the direction of rotation of the Push Pull
torch
As an option, two different gas monitoring systems are avail-
able
Gas flow monitor:
Here the minimum gas flow rate can be adjusted. If the gas
flow rate falls below this minimum value, the welding ma-
chine goes into fault and displays the corresponding error
message.
(0.0 = Gas flow monitor is deactivated)
Gas pressure monitor:
Here you can switch the gas pressure monitor on and off. If it
falls below this threshold, the welding machine goes into fault
and displays the corresponding error message.
The activation speed of the water monitoring can be set here.
This is 10 seconds as standard.
Standby time can be adjusted here.
Screensaver time can be adjusted here.
The type of compensation mode can be selected here.
Welding circuit resistance – automatic resistance measure-
ment via power source.
Welding cable length – direct adjustment of welding cable
length.
Setting the welding cable length.
This improves the welding behaviour with long welding ca-
bles.
The parameter display changes according to the selections
made in menu M4-18.
Welding circuit resistance calibration.
See "11 Welding circuit resistance measurement" on Page
42.
The parameter display changes according to the selections
made in menu M4-18.
Here you can set the brightness of all LEDs
Here you can set the contrast of the graphic display A52
909.3059.9-03
Note
- 51 -