Maintenance - SATA jet X 5500 Mode D'emploi

Masquer les pouces Voir aussi pour jet X 5500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 165
Operating Manual SATAjet X 5500 RP/HVLP (DIGITAL)
EN
* otherwise risk of corrosion
** otherwise damage of the electronic components of DIGITAL
spray guns
• Check spray pattern after cleaning the nozzle set!
• Further tips concerning cleaning can be found at www.sata.com/TV.
9.

Maintenance

• Prior to maintenance, disconnect spray gun from the compressed air
circuit!
• Disassemble and install components very carefully! Exclusively use
included special tools!
9.1. Replacing the nozzle set
and [7-6]
Every SATA nozzle set consists of "paint needle" [7-1], "air cap" [7-2]
and "fluid tip" [7-3] and has been hand-adjusted to provide a perfect
spray pattern. Lubricate both paint needle [7-1] in the paint needle area
(approx. 3 cm in front of the needle sleeve, paint needle spring) and ma-
terial flow control screw [1-11]. Therefore, always exchange the complete
nozzle set. After installation, please adjust material flow according to
chapter 7.2.
9.2. Replace paint needle seal
The needle needs to be replaced if spray medium starts to leak from the
self-adjusting paint needle pack. Remove trigger guard according to [8-
2]. After removal, check paint needle for damage, replace nozzle set if
necessary. When installing the trigger guard, make sure that the ironing
roll is positioned correctly [8-2]. After installation, set material throughput
according to chapter 7.2.
118
Notice!
Warning! Attention!
[7-1], [7-2], [7-3], [7-4], [7-5]
– Steps: [8-1], [8-2] and [8-3]

Publicité

Table des Matières
loading

Table des Matières