Operating Manual SATAjet X 5500 RP/HVLP (DIGITAL)
years. To exclude measurement errors, the display will be shut-off in case
of insufficient battery capacity. According to display and use, the battery
has to be exchanged within the following time frames:
Display:
Battery symbol
Exclamation marks (flashing)
Display "Lo
" upon switching-on
b
Screw in new battery compartment lid with pre-mounted sealing (Art. No.
1057414 including battery) hand-tight and check function.

10. Troubleshooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
Air bubbles appearing
in the gravity flow cup
Air bubbles appearing
in the gravity flow cup
4-5 weeks
2-3 weeks
<1 week
Cause
Fluid tip has not been
properly tightened
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity flow
cup
Defective paint needle
sealing

Corrective action

Tighten fluid tip [2-1]
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean nozzle set,
chapter 8, or replace,
respectively, chapter
9.1
Refill gravity flow cup
[1-6]
Replace the paint nee-
dle sealing, chapter
9.3