Malfunction
Spray pattern is too
small, crooked, lop-sid-
ed or splitting
Round/flat spray con-
trol cannot be regu-
lated
Spray gun does not
shut-off air
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Black digital display
Material leaks from
behind the paint nee-
dle sealing
122
Cause
Clogged air cap drill-
ings
Damaged fluid tip (fluid
tip aperture)
Regulation valve dirty
Clogged air piston seat
or worn air piston.
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long.
Unsuitable cleaning
solutions
Spray gun has been
soaked in cleaning
solution for too long
Wrong positioning of
the spray gun inside
the gun washing ma-
chine
Defective or missing
paint needle sealing.
Clogged or damaged
paint needle.
Corrective action
Clean air cap, observe
chapter 8
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
Remove round/flat
spray control, repair or
replace it, chapter 9.7
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
Cleaning, observe
chapter 8, get a
replacement spray
gun body.
Cleaning, observe
chapter 8, get a re-
placement digital unit
Replace / insert paint
needle sealing, chap-
ter 9.3
Replace nozzle set,
chapter 9.1; replace
paint needle sealing, if
necessary, chapter 9.3