Cleaning Of The Spray Gun - SATA jet X 5500 Mode D'emploi

Masquer les pouces Voir aussi pour jet X 5500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 165
Operating Manual SATAjet X 5500 RP/HVLP (DIGITAL)
8.

Cleaning of the Spray Gun

• Prior to cleaning, please disconnect the spray gun from the com-
pressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun and gravity flow cup completely, dispose of paint
material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, bases, pickling agents, unsuitable
regenerates or other aggressive cleaning solutions!*
• Do not soak spray gun in cleaning solution! *Cleaning solution
should never penetrate the air passages!
• Do not clean cover plate of the electronic pressure display with point-
ed, sharp or rough objects!
• Drillings are to be cleaned with SATA cleaning brushes or SATA nozzle
cleaning needles only. The use of other tools may cause damage or
may affect the spray pattern. Recommended accessory: cleaning kit
Art. No. 64030.
• Exclusively use spray gun washing machines recommended by SATA!
Please observe the operating instructions!
• The air passages have to put under pressure with clean compressed air
during the entire cleaning process!
• Nozzle head has to point downwards!
• Remove the spray gun from the washing machine after the
cleaning process!*
• Never use ultrasonic cleaning devices - leads to damage of noz-
zle set and gun surface!**
• After cleaning, the spray gun, the material passages, the air
cap including thread as well as the gravity flow cup have to
be blown dry with clean compressed air!*
Warning! Attention!
**
,
EN
117

Publicité

Table des Matières
loading