Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating instructions SATAjet 4000 B RP/HVLP (DIGITAL)
EN
• Make sure that spindle pick-up is free of material and paint residues,
remove residues and clean with solvent, if necessary
2. Installation and positioning of the new spindle [a, b]
• Screw in spindle [11-3]
• Turn spindle nut [11-3] to position 6 o'clock using a wrench (size 6)
[11-4]
3. Positioning and assembly of control knob [c]
• Position of knob [11-2] has to be according to illustration (line in the
knob has to be in vertical position)
• Hand-tighten screw [11-1] (Torx T20) in the knob – hold knob in the
position while tightening
9.8. Replacing the Battery (DIGITAL)
• Replace the battery outside of explosive areas only!
• Strictly observe the safety instructions in chapter 6.4.2!
According to the intensity of use, the battery will last between 1 to 3 years.
When the battery symbol appears on the pressure display, the battery has
to be exchanged within the next 2 to 3 weeks. The battery is empty when
no pressure is indicated with the spray gun inlet pressure exceeding 0.2
bar / 3 psi (trigger fully pulled). Tighten new battery lid with pre-assembled
sealing (Art. No. 165993 including battery) and check functionality.

10. Troubleshooting

Malfunction
Fluttering/spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
124
Warning! Risk of explosion!
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
[12-1] and [12-2]
Corrective Action
Tighten fluid tip [2-1]
with universal spanner
Replace air distribu-
tion ring, as it will be
damaged during disas-
sembly