SATA jet 4000 B Mode D'emploi page 483

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 169
Operating instructions SATAjet 4000 B RP/HVLP (DIGITAL)
Malfunction
Air bubbles appearing
in the gravity flow cup
Spray pattern is too
small, crooked, lop-sid-
ed or splitting
No function of round/
flat spray control - con-
trol knob can still be
turned
Round/flat spray con-
trol cannot be regu-
lated
Spray gun does not
shut-off air
Cause
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity flow
cup
Defective paint needle
sealing
Clogged air cap drill-
ings
Damaged fluid tip (fluid
tip aperture)
Air distribution ring has
not been positioned in
correct location (pin is
not located in the drill-
ing) or damaged
Regulation valve dirty
Clogged air piston seat
or worn air piston
Corrective action
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean nozzle set,
chapter 8, or replace,
respectively, chapter
9.1
Refill gravity flow cup
[1-6]
Replace the paint nee-
dle sealing, chapter
9.3
Clean air cap, observe
chapter 8
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
Replace air distribution
ring making sure it has
been positioned cor-
rectly when inserting it,
chapter 9.2
Remove round/flat
spray control, repair or
replace it, chapter 9.7
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
US
483

Publicité

Table des Matières
loading

Table des Matières