Mechanical installation
Motor mounting
Preparation
1. Remove terminal box of the motor
– If space is at a premium, remove the terminal board as well.
2. Connect the motor wires for the connection of the terminal board to terminal X2
with the terminal board
– Cable length 20 cm
3. Mark the position of the cable glands on the carrier housing and cut out the
openings
4. Insert the cable glands
5. Insert terminal box seal of the motor 0 again
6. Insert flat gaskets 1 into the elongated holes of the adapter plate
7. Screw the adapter plate with appropriate screws onto the motor
8. Cut out the hole for the cable 2 in the fan module
9. Place the fan module onto the adapter plate
10. Place the carrier housing onto the fan module and screw it with 4 screws M5 x 65
mm (scope of supply) onto the adapter plate
11. Cables which are led into the carrier housing must be stripped. The following applies
to all shielded cables:
– Strip 10 cm of the cable sheath
– Remove the shielding of the cable cores on a length of 8 cm
– 2 cm of the shield are needed for safe shield connection