Electrical connection

5.1
Fig. 9:
5.2
When fitting the equipment in a metal or copper line, potential equalisation should be established as
shown in the following diagram.
Warning!
STOP
If functional earthing is connected up together with auxiliary power (left-hand plug) on the plug (point A),
then the line which is connected up to point B must have the same potential as point A. If this is not the
case, then connections may only be made to one point - either in plug (point A) or outside on equipment
(point B). We recommend connecting up functional earthing at point B. Refer to fig. 10.
Fig. 10:
GB 14
FXL5000 (Miniflow)

Signal outputs and auxiliary power

2
1
Consult the type plate for the equipment variant. You will find the relevant information
under the key word "variant".
The pin assignment for each variant is summarised in the following table.
Variant 1 (without display) or
variant 3 (with display)
Variant 2 (without display) or
variant 4 (with display)
Variant 5 (with display)

Earthing

A
B
Potential equalisation only with metal piping
Connection
Receptacle acc. to DIN 43650 with PG 9 screw connection,
line cross-section up to max. 1.5 mm2, type of protection IP 65
Open up plug and connect up as follows:
Left-hand plug = auxiliary energy
1 24 V AC/DC
2 GND
Functional earthing
3
Right-hand plug = signal outputs
Pin 1+2 20 mA or contacted input (option)
Pin 3+
pulse/contact output opto
4
(Also refer to "Connection
peripherals" chapter)
Assembling plug
1. Use screw 1 to open the plug.
2. Take inner section 3 out of outer section 4.
3. Energise in accordance with connection arrangement.
4. The plug is assembled in reverse order.
Pulse output, passive, optocoupler
Not assigned
Pulse output, passive, optocoupler
Current output 0/4 - 20 mA
Pulse output, optocoupler
Current input, optocoupler
5 Electrical connection
Functional earthing
2
1
2
4
3
1
+ pin 3 - pin
+ pin 1 - pin 2
+ pin 3 - pin
+ pin 2 - pin 1
+ pin 3 - pin
+ pin 2 - pin 1
D184B112U04