DGPI(L)−...−AI F
Electric
Measuring system
Protection class (measuring system incl.
housing and connections)
Electrical connection
Interface
Data protocol / transmission rate
Linearity
Resolution
Power supply
Current consumption (start/stop)
Temperature coefficient
EMC resistance (with earthed cylinder)
Festo DGPI(L)−...−AIF 0409a English
Magnetostrictive, contactless, absolute measuring
IP65
(with correctly fitted connector socket with cable)
6−pin round plug as per DIN 45322
CAN as per ISO/DIS 11898
SPC−AIF / 1 Mbit/s
< ± 0.02 % F.S. (min. ± 50 ìm)
0.01 mm
24 V DC (+ 20 / − 15 %)
90 mA typ.
< 15 ppm / °C
DIN EN 61000−6−2 / DIN EN 61000−6−3