Switching Off; Circuit Breaker; Maintenance Table - SDMO ALIZE 3000 Manuel D'utilisation Et D'entretien

Groupes électrogènes
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
4.2.2 Direct current operation
The 12 V direct current is only used for charging car batteries.
The generating set should be switched off before connecting the electric cables.
Do not try to start a car engine if the generating set is connected to the battery.
Warning
❶ Connect the cables to the battery terminals then to the generating set alternating current sockets observing the polarities (the
generating set + cable to the battery + cable and the generating set – cable to the battery – cable)
❷ Start the generating set to charge the battery.

4.3. Switching off

When the generating set is turned off, the engine continues to give off heat.
Appropriate ventilation should be provided after the generating set is turned off.
To stop the generating set urgently, place the engine switch on "OFF" or "О".
Warning
Take the plugs out of the sockets and allow the engine to run without any charge for 1 to 2 minutes.
Place the engine switch (no. 10, diag. A) on "OFF" or "О" and the set will stop.
Close the fuel tap (no. 14, diag. A).
5. Safety features (if fitted, see specifications table)
5.1. Oil cut-out
This mechanism is designed to prevent any damage to the motor resulting from lack of oil in the motor sump. It automatically cuts out
the motor. If the motor stops and will not restart, check the motor oil level before looking for any other cause of the problem.

5.2. Circuit breaker

The electrical circuit of the set is protected by several magnetothermal, differential or thermal cut-out switches. Any overload and/or
short circuits cause the supply of electrical energy to be cut.
6. Maintenance schedule
6.1. Reminder of use
The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme.
However, it should be added that it is the environment in which the generating set is operating which determines this programme.
Accordingly, if the set is used in extreme conditions, shorter intervals between maintenance procedures should be adopted.
These maintenance schedules apply only to generating sets running on fuel and oil, that conform to the specifications given in this
booklet.

6.2. Maintenance table

Carry out these maintenance procedures at
Part
Engine oil
Air filter
Fuel filter
Spark arrester
Spark plugs
Valve clearance
Strainer and petrol tank
Cleaning the generating set
Fuel line
Note: * This operation should be carried out by one of our agents
(1): Perform air filter maintenance more frequently for operation in dusty locations.
whichever of the two intervals is
reached first
Check the level
Change
Check
Clean
Clean
Clean
Check / clean
Check / adjust
Clean
Check (replace if necessary)
Each time it is
After the
used
first 20
hours of use
Every 2 years (*)
Every 3
Every 6
months or
months or
50 hours
100 hours
• (1)
Every 12
months or
300 hours
•(∗)
• (*)
• (*)