4. Using the generator set

Before use:
- make sure you know how to stop the generating set in the event of an emergency,
- make sure you completely understand all the controls and operations.
Warning
To stop the generating set urgently, place the engine switch on "OFF" or "О".

4.1. Starting procedure

Ensure that generating set is correctly earthed (see the Earthing section).
Open the fuel tap (diag. A – no. 14).
Position the starter handle (diag. A – no. 13) in the "
N.B: Do not use the choke when the engine is warm or when the atmospheric temperature is high.
Move the on/off control (diag. A - no. 7) to "
Slowly pull the starter-recoil reel handle (diag. A – no. 5) once, until there is some resistance then let it return gently.
Then pull the starter-recoil reel handle (diag. A – no. 5) sharply and rapidly, until the engine starts.
Slowly place the choke tab (diag. A - no. 13) in the "
using the generating set.
If the engine has not started, repeat the procedure until the engine starts while gradually opening the choke.
4.2. Operation
When the generating set speed has stabilised (approximately 3 minutes):
Check that the green button on the circuit breaker (diag. A - no. 12) is depressed. Push it in if necessary.
Connect the equipment to be used to the generating set electrical sockets (diag. A – no. 11).
N.B.: These generating sets are fitted with "Schucco" sockets: there may occasionally be instances where these are not
compatible with certain devices. In this case, our agents can provide an adaptor free of charge on request (proof of purchase
required).

4.3. Switching off

Disconnect the electric sockets (diag. A - no. 11) to allow the engine to run with no load for 1 or 2 minutes.
Move the on/off control (diag. A - no. 7) to "OFF" or "O": the generating set will stop.
Close the fuel tap (diag. A – no. 14).
Always ensure that the generating set is suitably ventilated.
Even when the unit is turned off, the engine continues to give off heat.
Warning
" position.
O
N
" or "
I
" .
O
N
"
I
"
" position and wait until the engine temperature starts to increase before