Appendix 1: Technical data
According to EU 305/2011 (construction products); EU2015/1185 (ecodesign) and EU2015/1186 (labelling).
Model VISTA 700i/V2 / VISTA 800i/V2
Model
Nominal output/direct heat output
Flue connection (diameter)
Weight
Preferred fuel
Fuel property, max. length wood
Electrical connection
Mass flow of flue gasses
Temperature increase measured in the measurement section 260 K
Temperature measured at appliance exit
Minimum draught
CO emissions (13% O
at nominal heat output)
2
NOx emissions (13% O
at nominal heat output)
2
CnHm emission (13% O
) at nominal heat output
2
Particulate emission (13% O
Useful efficiency at nominal heat output
Seasonal energy efficiency
Energy efficiency index
Energy efficiency class
Electricity consumption at nominal heat output
Electricity consumption at minimal heat output
Electricity consumption in standby mode
Type of heat output/room temperature control
Subject to change because of technical improvements
) at nominal heat output
2
700i/V2
800i/V2
10 kW
11 kW
150 mm
180 mm
95 kg
110 kg
Wood, moisture
Wood, moisture
<25%
<25%
50 cm
60 cm
230 V, 50 Hz, 0.5 A
7.1 g/s
9.5 g/s
290 K
335 ℃
375 ℃
13 Pa
13 Pa
0.08 % (998
0.07 % (920
mg/Nm³)
mg/Nm³)
112 mg/Nm³
67 mg/Nm³
56 mg/Nm³
20 mg/Nm³
19 mg/Nm³
9.4 mg/Nm³
83%
78%
72.30%
67.32%
109.6
102.42
A+
A
0.05
0.05 kW
0.025
0.025 kW
0 kW
0 kW
Single-phase heat output, no room tem-
perature control
D OVRE