Flue
B
Fireproof material or connector
C
Cover plate
D
Insulation material (minimum 5 cm)
E
Fireproof wall
F
Combustible wall
G
Ventilation space (minimum 15 mm)
H
Fireproof ceiling
I
Combustible ceiling
J
Convection air opening
K
Insulation (optional)
L
Fireproof base
M
Combustible base
N
Opening to prevent pressure build-up
O
Connection pipe
P
Convection air to other space
Preparing the outside air
connection
If the appliance is placed in a space that is insuf-
ficiently ventilated, you can connect to the appliance
the connection set for the intake of outside air. The
air intake pipe is 100 mm in diameter. If using a
straight pipe, this pipe may be up to 12 metres long.
When using attachments such as bends, reduce the
Subject to change because of technical improvements
09.20015.057
I
N
J
K
O
L M
maximum length (12 metres) by 1 metre per attach-
ment.
A
1
2
If you decide to use the outside air connection (A) or
(B), use the two screws (1) to attach the provided
cover plate (2) to close off the inside air.
B
09-20024.007
D OVRE
17