All flammable materials must be removed
from under the appliance or protected by at
least a 6 cm concrete slab.
Flammable walls bordering the appliance
must be protected by at least a 10 cm stone
wall and 5 cm insulation.
Protect non-flammable walls bordering the
appliance with at least 2.5 cm insulation to
avoid cracking.
Protect a flammable floor from heat radiation
and falling ash by means of a fireproof pro-
tective plate. See the appendix "Distance
from combustible material".
Keep enough distance between the appliance
and combustible materials such as furniture.
Ensure sufficient ventilation around flam-
mable materials such as a mantelpiece. See
appendix "Distance from combustible
material".
Carpets and rugs must be at least 80 cm away
from the fire.
Do not place any flammable materials within
50  cm of any convection outlets.
D OVRE
10
Product description
Vista 701i/V2 and Vista 801/V2 (cast iron):
1
2
3
4
6
7
9
10
1. Convection air connection
2. Door
3. Decorative frame
4. Air slide
5. Door latch
6. Insulation plates
7. Stove base
8. Cast-iron inner plates
9. Flue gas connection
10. Outside air connection
11. Magnets for the decorative frame
Subject to change because of technical improvements
5
8
11
09-20024.002