You may now close the battery cover and re-insert the screw.
Mount the ball-head joint on the wall with screws provided. Slide the back of
the sensor into the ball-head joint. The mounting angle can be adjusted.
Testing
Walk test should be performed after the motion sensor is mounted. Walk in the detected area, if
motion is detected, a red light inside the sensor will glow. If the red light does not glow, motion
has not been detected and you may need to re-position the sensor. Ensure you walk test all the
locations that you would like the motion sensor to cover.
Note:
- Perform the walk test after you have inserted the battery for more than 1 minute.
- Before performing the walk test, the sensor should not detect any motion.
- After motion is detected once, the sensor will not be triggered unless no motion is
detected for 20 seconds. Therefore, wait for at least 20 seconds during walk
testing between 2 activations.
Caution:
When installing the motion sensor, avoid placing it near heat or cold producing devices (i.e. A/C or furnace
vents, fans, ovens, space heaters, etc). Air movement,especially caused by changes in temperature may
trigger the Motion Sensor and cause false alarms. Please carefully test your Motion Sensor so that it will only
be triggered by wanted movement.
You have now successfully installed and programmed the Control Panel and its sensors. Please follow the
rest of the instructions for operations and advanced programming.
The Control Panel is always in one of the 2 operating modes:
1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.
Alert Mode
The Control Panel will be in alert mode automatically if the system is not armed. Alert mode allows users
inside the premises to know what sensor is triggered. It is intended to be used when someone stays inside
the premises.
In alert mode, the control panel will give you notification of the triggered sensor(s) by voice announcement,
unique beeping and LED flashing.
1
Number of beeps
2
Number of flashes of zone LED
Note:
- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors can be programmed to the
control panel. Please refer to page 21, "Sensor Location Selection Guide" for detail information.
INSTALLATION
OPERATION
Zone of the triggered sensor
Sensor number of the triggered sensor
8
DETECTING AREA: (unit = meter)
1.2M
14
55
55
11
12
10
8
6
27
22
22
4
2
M