Testing:
After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or
window will result in the following:
1. Beeping - The number of beep represents the zone number.
2. Zone LED flashing - Number of flash represents the sensor number.
Note:
- Try to mount the sensors as far away from the floor as possible to avoid damaging them. Mounting the
sensors at a higher position will also result in better operating range.
- Do not mount the sensor to the exterior of the door / window, always mount the sensor to the interior side of
the door / window to avoid being damaged or stolen by non-intended users.
Installing Motion Sensor
The motion sensor is most suitable for guarding a large area such as living room, family room, or bedroom. It
can also be used to monitor a hallway or stairway.
Insert Battery
Undo the screw on the back of the motion sensor and remove the battery
cover. Connect a 9V alkaline battery to the battery connector. Please note
the polarity.
If you are planning to install the motion sensor outdoor, you should reduce
the sensitivity by placing the jumper at location "2".
For indoor application, if you want to reduce the sensitivity, you can change
the jumper setting to "2" as well.
Jumper Location 1
Jumper Location 2
Caution:
Depending on the environment, if you experience a false trigger when the motion sensor is placed outdoors,
you should relocate it or even place it indoors. Wind blowing at a tree, or direct sunshine could cause a false
trigger. Therefore, if the location at where the motion sensor is mounted could cause a false trigger, you
should change the mounting location for such sensor.
For outdoor monitoring, please refer to page 19 to program the motion sensor to Alert Zone.
INSTALLATION
1. Beep ___Beep ___
Beep ___Beep ___
............
High Sensitivity
Low Sensitivity
7
2. Single flash
Sensitivity