Continuous Mode

Continuous Nebulization Tube Set
The Aerogen Continuous Nebulization Tube Set is an accessory specific
to the Aerogen Solo nebuliser which enables safe continuous infusion of
liquid medication for aerosolisation.
Note: Place the syringe cap on the syringe after it is filled with medication.
Tethered Silicone Plug
A
Figure 17. Continuous Nebulization Tube Set
1. Ensure the Aerogen Solo nebuliser is firmly fitted into the Aerogen Solo
T-piece in the breathing circuit.
2. Remove the syringe cap from the medication-filled syringe.
3. Attach the syringe end of the tubing onto the syringe.
4. Prime the tubing until the medication reaches end of tubing (Point A).
Note: The tubing priming volume is maximum 3.65 mL.
5. Unplug the tethered silicone plug from the Aerogen Solo nebuliser, but
do not remove it from the nebuliser.
6. Screw the nebuliser end of the tubing onto the top of the nebuliser.
7. Insert the syringe filled with medication into the syringe infusion pump
(pump not shown in Figure 17) and set the appropriate flow rate (refer
to pump manual or manufacturer for guidance).