26. Programming measures using the "SELF-LEARNING" function
The water doses for coffee and the hot water doses can
also be set using the "SELF-SETTING' function:
Coffee measures
coffee and insert it in the dispenser unit.
and press the button to be programed. Keep it pressed
until the desired level is reached in the cup or container.
During this phase, the setting for the volumetric dosage
pulses (top right of display) is increased. When the key is
released, the setting reached is memorized and appears
under the programmed key.
3 - Starting from step 1, continue programing, as desired,
on all the coffee buttons.
STOP
press and hold the STOP button for at least 8 seconds
or until you hear a buzzer sound that will keep sounding
throughout the programing. The menu below will appear
on the display, showing the keys with the relative quantities
for water for the coffee.
Group 1
090
150
Hot water measures
1 - Press the button to be programed and keep it pressed
until the desired level is reached in the cup.
During this phase the time in seconds (top right of
setting reached is memorized and appears below the
programmed key.
water buttons
3.5
2 - Starting from step 1, continue programing, as desired,
on all the water buttons.
27 EN
SELF-LEARNING
DV:
000
STOP
080
160
SELF-LEARNING
t: 3.5
3.5