CAME ZLX24MA Mode D'emploi page 82

Masquer les pouces Voir aussi pour ZLX24MA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Photocell BUS <n>
Associate a function with the photocell BUS <n> input.
<n> is between 1 and 8 and corresponds to the address set on the photocell dip-switch
b1-b8
<Mode> BUS fl ashing beacon
Choose the operating mode for the lights connected to the BUS connector.
The function only appears if there is a BUS fl ashing beacon connected.
b40 >
<Opening colour> BUS fl ashing beacon
Set the BUS fl ashing beacon colour during gate opening.
The function only appears if there is a BUS fl ashing beacon connected.
During the count preceding automatic closure, the colour of the fl ashing beacon is the same as during opening.
b40 >
OFF (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C13 = Reopen while closing, with immediate stop once the obstruction has been removed,
even if the gate is not in motion
C23 = Open command
C24 = Close command
L1
L2
0 =Flashing beacon (Default)
The light fl ashes during opening and closing.
1 = Cycle fl ashing beacon
The light fl ashes during opening and closing and remains on during the
countdown before automatic closure.
The colour of the fl ash depends on the functions [L2], [L3]
and [L4].
1 = White (Default)
2 = Yellow
3 = Orange
4 = Red
5 = Purple
6 = Blue
7 = Light blue
8 = Green

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zlx24mr

Table des Matières