Additional light
Choose the operating mode for the lighting device connected to output E3.
F18
Automatic closure
Set the time before automatic closure, once the opening travel end point has been reached or once the photocells have
caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
F19
Automatic closing after either partial or pedestrian opening
Set the time before automatic closure after a partial opening command has been performed or after the photocells have
caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a
complete stop, during a power outage or if there is an error.
F20
Pre-fl ashing time
Adjust the time for which the beacon is activated before each manoeuvre.
F21
M1 opening delay time
Adjust the delayed opening of the fi rst leaf compared to the second.
F23
M2 closing delay time
Adjust the delayed opening of the second leaf compared to the fi rst.
F24
Courtesy time
Defi ne how many seconds the additional light (set up as courtesy light) stays on after an opening or closing manoeuvre.
F25
OFF (Default)
1 = Cycle light
The lamp stays on during the manoeuvre.
The light remains off if an automatic closing time is not set.
2 = Courtesy lamp
The light switches on when a manoeuvre starts and remains on once the manoeuvre has
fi nished, for the time set under the function [F25 Courtesy time].
OFF (Default)
From 1 to 180 seconds
OFF
1 to 180 seconds (Default 10)
OFF (Default)
1 to 10 seconds
OFF
1 to 10 seconds (Default 2)
OFF
1 to 25 seconds (Default 2)
60 to 180 seconds (Default 60)