CAME ZLX24MA Mode D'emploi page 75

Masquer les pouces Voir aussi pour ZLX24MA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Opening slowdown point for M1
Set the percentage of the total travel to be used for M1 opening slowdown.
F37
M1 closing slowdown point
Set the percentage of the total travel to be used for M1 closing slowdown.
F38
M1 opening approach point
Set the percentage of the total travel to be used for M1 opening approach.
F39
M1 closing approach point
Set the percentage of the total travel to be used for M1 closing approach.
F40
Opening slowdown point for M2
Set the percentage of the total travel to be used for M2 opening slowdown.
F41
M2 closing slowdown point
Set the percentage of the total travel to be used for M2 closing slowdown.
F42
Opening approach point for M2
Set the percentage of the total travel to be used for M2 opening approach.
F43
Closing approach point for M2
Set the percentage of the total travel to be used for M2 closing approach.
F44
Reduce speed
Reduce the minimum voltage applicable to the motor.
The parameter is only available for the Stylo ME and Stylo RME motors.
F45
OFF (Default)
1% to 50%
OFF (Default)
1% to 50%
0.5% to 25.0% (Default 8.0%)
0.5% to 25.0% (Default 8.0%)
OFF (Default)
1% to 50%
OFF (Default)
1% to 50%
0.5% to 25.0% (Default 8.0%)
0.5% to 25.0% (Default 8.0%)
OFF (Default)
1% to 50%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zlx24mr

Table des Matières