CAME ZLX24MA Mode D'emploi page 49

Masquer les pouces Voir aussi pour ZLX24MA:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description
801QA-0050
ZLX24MA - Multifunction control panel, with 230 VAC power supply, for 24 V swing gates with two leaves, with programming
display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN, 2 safety inputs and
memory space for up to 250 users.
801QA-0070
ZLX24MR - Multifunction control panel, with 120 VAC power supply, for 24 V swing gates with two leaves, with programming
display and signalling, safety device self-diagnostics, adaptive speed and torque technology, BUS CXN, 2 safety inputs and
memory space for up to 250 users.
Technical data
MODELS
Power supply (V - 50/60 Hz)
Motor power supply (V)
Board power supply (V)
Standby consumption (W)
Power (W)
Transformer thermal protection (°C)
Colour
Operating temperature (°C)
Storage temperature (°C)*
Cycles/hour
Consecutive cycles
Protection rating (IP)
Insulation class
Average life (cycles)**
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very
high or very low temperature.
(**) The average product life is a purely indicative estimate. It applies to compliant usage, installation and maintenance
conditions. It is also infl uenced by other factors, such as climatic and environmental conditions.
Fuse table
MODELS
Line fuse
Control-board fuse
Accessory fuse
ZLX24MA
230 AC
36 DC
26 AC
3
360
120
RAL 7040
-20 ÷ +55
-20 ÷ +70
20
20
54
I
100.000
ZLX24MA
3.15 A F
1.6 A T
1.6 A F
ZLX24MR
120 AC
36 DC
26 AC
3
360
120
RAL 7040
-20 ÷ +55
-20 ÷ +70
20
20
54
I
100.000
ZLX24MR
4 A F
1.6 A T
1.6 A F

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zlx24mr

Table des Matières