Electricalinstallation
9.2.2
Electrical installation 24 V DC with
circular plug-in connector
Connect the positioner according to the table.
6
7
8
1
Fig. 14: Circular plug M12 x 1, 8-pole
Input signals of the control center (e.g. PLC)
Wire
Pin
Configuration
color
3)
1
white
Set-point value
+
(0/4 ... 20 mA)
2
brown
Set-point value
GND
5
grey
Digital input +
6
pink
Digital input
GND
Tab. 6:
Pin assignment - input signals of the control center
Type 8694
5
4
3
2
External circuit / signal level
1
+ (0/4 ... 24 mA)
GND
2
5
+
0 ... 5 V
10 ... 30 V (log. 1)
identical to Pin 3 (GND)
Operating voltage
Wire
Pin
Configuration External circuit
color
3)
3
green
GND
4
yellow
+ 24 V
Tab. 7:
Pin assignment - operating voltage
Output signals to the control center (e.g. PLC) - (required for
analogue output option only)
Wire
Pin
Configuration External circuit / signal level
color
3)
8
red
Analogue
position
feedback +
7
blue
Analogue
position
feedback GND
Tab. 8:
Pin assignment - output signals of the control center - option
(log. 0)
When the supply voltage is applied, the positioner is operating.
Actuate the automatic adjustment of the positioner, as described
in the chapter entitled "10.2 Automatic adjustment X.TUNE".
The indicated colors refer to the connecting cable available as an
3)
accessory (919061).
24 V DC ± 10 %