36
Maintenance and Service

4.3 Error Codes

EN
An error message is displayed when the mains voltage is wrong or thermal. If you do not want the welding performance to be affected during the
installation process, the parameters such as wire diameter, torch, consumables used in the torch, wire type, wire diameter and gas type should be
taken into account.
Error Code
E01
E02
E03
E04
E05
E06
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Error
• There may be problems at different points in
Communication Error
the machine
• The machine's run time rate may have been
exceeded
• Fan may not be operating
Thermal Protection
• The air inlet and outlet ducts may have been
blocked
• The machine operating environment can be
extremely hot or lack of air
• The machine may have been overloaded
Overcurrent Failure
• There may be problems at different points in
the machine
Low mains voltage
• Mains voltage may have decreased
Temperature Sensor
• Temperature sensor may have failed or there
Reading Failure
may be an electrical connection problem
High mains voltage
• Mains voltage may have increased
Reason
• Contact the authorized service
• Wait for a while to allow the machine to cool
• Visually inspect the fan for proper operation.
• Open the air ducts
• Ensure that the machine is placed in an area
• Contact the authorized service
• Contact the authorized service
• Check the mains connection cables and
• Contact the authorized service
• Check the mains connection cables and
ID 500 M/MW PULSE EXPERT
Solution
down. If the failure disappears, try to run the
machine at lower amperage values
Please contact the authorized service if it
does not operate
where it can work operate comfortably
voltage. Make sure that the correct voltage
input is provided. If the mains voltage is
normal, contact the authorized service
voltage. Make sure that the correct voltage
input is provided. If the mains voltage is
normal, contact the authorized service