24
Operation
6 TRIGGER MODE: The parameters on page 5 of the menu will be active. According to the parameters set on page 5, the 6-trigger mode will run.
EN
You can use the 6 trigger functions to make a crater or prevent start and end welding errors.
For instance;
Welding Current: 200 A, Initial current: 200%, End current: 50% and End time: Set to 2 seconds.
In this case, the Initial current will be 400A, to be 200% of the main current. The end current will be 50 A, that is 50% of the main current.
Welding Start and End;
• Press and hold the torch trigger.
• Shielding gas flow starts as long as the pre-gas period and continues at the initial current.
• The torch trigger is released and the current decreases during the specified start time and the main current value is reached then the operation
continues at the main current.
• Press and hold the trigger. Transition from main current to end current is done, the process continues at the end current.
• Release the trigger when you want to finish the process, the process ends at the end of the final gas time.
METHOD: It is the pnt welding to be mentioned in the mode. The welding continues for the specified welding period and ends at the end of the period.
No welding will be performed if as long as the defined void period. This period will continue as long as the trigger is not released. Welding Time: 0.2-9.9
and void time: It is between 0.0 and 9.9 seconds.
It should be preferred when the same welding seam and penetration are desired every time. The lengths of the welds made in Method mode will
be equal.
b) ARC ON TIME
When the method mode is selected, the welding time will be set.
Setting Range
• 0.2-9.9 sec
c) )ARC OFF TIME
When Method mode is selected, the non-welding time will be set.
Setting Range
• 0.0- 9.9 sec
d) SOFT START
Adjust the speed of the wire when it first comes.
Setting Range
• Active / Passive
The fast incoming wire gives the user a sense of pushing backwards at the first moment. If you activate the clicking setting, the wire comes slowly and
accelerates as soon as the welding starts. So the feeling of push back disappears.
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
PrG : Pre-Gas Period
IC : Initial current
ST : Start Time
I
: Welding Current
FT : End time
FC : End Current
PoG : Final Gas Period
ID 500 M/MW PULSE EXPERT
www.magmaweld.com