a) TRIGGER
Trigger mode selection will be made.
Setting Range
• 2 Trigger
• 4 Trigger
• 6 Trigger
• Method
Press the Trigger
2 TRIGGER MODE: When the torch trigger is pressed, welding starts and the trigger will be held pressed until the welding ends. Releasing the trigger
will end the welding.
Welding Start;
• Press and hold the torch trigger.
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period, the wire feed motor runs at a slow speed.
• Welding current increases when the workpiece is reached.
4 TRIGGER MODE: When the torch trigger is pressed and released once, welding starts and there is no need to hold it pressed until the welding ends.
Pressing and releasing the trigger again will end the welding process.
Welding Start;
• Press and hold the torch trigger.
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period, the wire feed motor runs at a slow speed.
• Welding current increases when the workpiece is reached.
• Release the pressed torch trigger and the welding will continue.
www.magmaweld.com
Hold the Trigger Pressed
PrG : Initial Gas Time
I
: Welding Current
PoG : Final Gas Time
PrG : Initial Gas Time
I
: Welding Current
PoG : Final Gas Time
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
Release Trigger
Welding Termination;
• Release the pressed torch trigger.
• The wire feed motor will stop.
• The arc extinguishes after the set burn-back time.
• The process ends after the final gas period.
Welding Termination;
• Release the pressed torch trigger.
• The wire feed motor will stop.
• The arc extinguishes after the set burn-back time.
• The process ends after the final gas period.