Maintenance And Service; Maintenance - Magmaweld ID 500 M PULSE EXPERT Manuel D'utilisation

Masquer les pouces Voir aussi pour ID 500 M PULSE EXPERT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

34

Maintenance and Service

MAINTENANCE AND SERVICE
EN
• Maintenance and repairs to the machine must be carried out by a qualified personnel. Our company will not be responsible for any accidents that
may occur by unauthorized interventions.
• Parts that will be used during repair can be obtained from our authorized services. The use of original spare parts will extend the life of your machine
and prevent performance losses.
• Always contact the manufacturer or an authorized service designated by the manufacturer.
• Any unauthorized attempt other than by the manufacturer during the warranty period will cause all warranty provisions to be void.
• Always comply with the applicable safety regulations during maintenance and repair.
• Before performing any work on the machine for repair, disconnect the machine's power plug from the power supply and wait for 10 seconds for the
capacitors to discharge.

4.1 Maintenance

Daily Maintenance
• The wire feed mechanism must be kept clean and the roller surfaces must not be lubricated. Each time you
replace the welding wire, always clean the residues on the mechanism with dry air.
• The supplies on the optional TIG torch must be cleaned regularly. Should be replaced if necessary. It should be
ensured that these materials are original products for a long-term use.
Every 3 Months
• Do not remove the warning labels on the device. Replace worn / torn labels with new ones. The labels can be
obtained from the authorized service centers.
• Check the clamps and cables. Pay attention to the connections and strength of the parts. Replace damaged /
defective parts with new ones. Do not extend or fix the cables.
• Ensure that enough space for ventilation is available.
Every 6 Months
• Clean and tighten fasteners such as bolts and nuts. Check the electrode clamp and grounding clamp cables. Open
the side covers of the machine and clean with low pressure dry air. Do not apply compressed air to electronic
components at close distance.
• Replace the water in the tank of the water-cooling unit at periodic intervals with a soft, clean water and ensure
protection against freezing with antifreeze.
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems are encountered in your device.
Depending on the work load and contamination of your work environment, you can repeat the above processes more frequently.
Never operate the machine when covers are open.
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 M/MW PULSE EXPERT
www.magmaweld.com

Publicité

Table des Matières
loading

Table des Matières