28
Operation

3.3 Remote Control

EN
With a torch with suitable properties and a connector, you can also change your welding current (wire speed) / welding voltage through the torch
without going near your machine.
Mode
Classic Mode
Smart Mode
Synergic Mode
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
1
2
Button
You can reduce your wire speed to the minimum tolerance value (-10%).
1
Setting Range : 0.5 m/min
You can increase your wire speed up to the maximum tolerance value (+10%).
2
Setting Range : 0.5 m/min
You can increase your welding voltage up to the maximum tolerance value
A
(+10%). Setting Range : 0.5 V
You can reduce your welding voltage up to the minimum tolerance value (-10).
B
Setting Range : 0.5 V
You can reduce your welding current to the minimum tolerance value (-10%).
1
Setting Range : 5 A
You can increase your welding current up to the maximum tolerance value (+10%).
2
Setting Range : 5 A
You can increase your welding voltage up to the maximum tolerance value (+ 10%).
A
Setting Range : 0.5 V
You can reduce your welding voltage to the minimum tolerance value (-10%).
B
Setting Range : 0.5 V
You can reduce your welding current to the minimum tolerance value (-10%).
1
Setting Range : 5 A
You can increase your welding current up to the maximum tolerance value (+10%).
2
Setting Range : 5 A
You can increase your welding voltage up to the maximum tolerance value (+10%).
A
Setting Range : 0.5 V
You can reduce your welding voltage to the minimum tolerance value (-10%).
B
Setting Range : 0.5 V
ID 500 M/MW PULSE EXPERT
A
B
Position