ID 500 M/MW PULSE EXPERT
PAGE 1
a) LANGUAGE
Menu language is selected.
Setting Range
• TR (Turkish)
• EN (English)
• FR (French)
• DE (German)
b) PROCESS
Welding process will be selected.
Setting Range
• MMA
• MIG/MAG
• Pulse (Pulse MIG/MAG)
• D.Pulse (Double Pulse MIG/MAG)
You need to adjust your connections and accessories according to the selected welding method. There is a separate outlet for the MMA method in
front of the machine.
c) MODE
Selecting from the METHOD menu creates a differentiation in the MODE menu options.
MMA
Setting Range
• Method
• Set/Carbon
• Rutile / Basic
If you select your source mode correctly, you will get better welded pieces. For example; the method mode should be selected for the welding
processes where continuous short welding seams will be made.
MIG/MAG
When the MIG/MAG welding method is selected in the METHOD menu, the modes will be as follows:
CLASSIC MODE
You can adjust your wire speed and welding
voltage in certain tolerance value ranges.
Wire speed will be adjusted between 1-24 m/
min, welding voltage will be adjusted between
15-40 V.
If you want to see which value the machine originally recommends and return to that value, simply press the adjustment button once.
www.magmaweld.com
MIG/MAG
Pulse (Pulse MIG/MAG)
Setting Range
Setting Range
• Classic
• Classic
• Smart
• Smart
• Synergic
• Synergic
SMART MODE
When selected, welding parameters such as wire
type, wire diameter, gas type must be selected
correctly. The machine will automatically adjust
the optimum voltage according to the selected
welding current. You can adjust the voltage by
turning the adjustment knob in the +/- direction
within a certain tolerance range.
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
D. Pulse (Double Pulse MIG/MAG)
Setting Range
• Classic
• Smart
• Synergic
SYNERGIC MODE
Welding parameters such as wire type, wire
diameter, gas type and thickness must be
selected correctly. Both the current and the
voltage will be automatically adjusted
according to the selected welding parameters.
The user can navigate both in the current and
voltage within a certain tolerance range. The
machine will automatically recalculate the
voltage according to the current value set at
the specified tolerance.
Operation