Error Code Definitions - BAFANG MAX Drive System Manuel

Masquer les pouces Voir aussi pour MAX Drive System:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.6

error Code Definitions

the MAX-C966 display can show e-bike faults. When a fault is detected, the icon
field one of the following error codes will be displayed:
Error Code
Error Description
"03"
Brake enabled
"04"
the throttle has not returned home
"05"
throttle fault
"06"
Low voltage protection
"07"
overvoltage protection
"08"
Motor hall signal cable fault
"09"
Motor phase cable fault
"11"
Controller temperature sensor failure
"12"
Current sensor failure
"13"
Battery temperature fault
"21"
Speed sensor fault
"22"
BMS communication fault
"30"
Communication fault
Error display
55
will be displayed. In the speed
Error-shooting Method
Check whether a brake cable is stuck
Check if throttle has returned home
Check the throttle
Check the battery voltage
Check the battery voltage
Check the motor module
Check the motor module
Check the controller
Check the controller
Check the battery
Check installation position of speed sensor
Replace the battery
Check the controller connection
DEALER MAnuAL Max Drive SySteM

Publicité

Table des Matières
loading

Table des Matières