4.3 QE44 electronic control panel
Open
Close
Emergency
Orange
Black
FA F C
BRAKE
Limit switch
FA Opening limit switch
FC Closure limit switch
Dip switches
Dip 1 Pre-flashing for opening
OFF = Absent
ON = Enabled (3s)
Dip 2 Speed selection for opening
OFF = Absent
ON = Enabled (3s)
P
OFF
OSITION ON
DUAL SPEED NOT AVAILABLE
Dip 3 Safety selection 1-8 for opening
OFF = safety device disabled for opening
ON = safety device enabled for opening
Adjustments (trimmer)
RP = Partial opening (optional)
LC = Pre-flashing time for closure (0-15 s)
TC = automatic closure time (0-30 s)
F5
C
N
T
8/40
LD1
FA
LD2
FC
LD3
Q.E.
13 12 11 0 -F +F
1 2 3
Blue
RP
White
Red
14 0 0 1 1 2 3A 3B 4 8 9 20 40 41
J10
J9
J8
R16
ON
DIP
W Z V Y U X
LC
TC
Signals (LED's)
LD1 8/40
OFF = safety devices not triggered
Flashing = safety device triggered
ON = opening command enabled
LD2 FA
ON = opening limit switch enabled
LD3 FC
ON = closure limit switch enabled
Accessory boards
"OPEN" Control accessories – directly connected to the
opening command (1-3): radio, magnetic coil, etc.
"SAFETY" Safety accessories - directly connected to the re-
versal safety device (1-8): photocells, etc.
T
"SAFETY"
O ENABLE THE
- 17 -
F4 = F630 mA
F5 = F5A
F4
L3 L2 L1
M
3~
F8 A
T S R
400
V~
,
J9
INPUT
REMOVE BRIDGE
0DT773 15/10/2003
DITEC S.p.A.
GB